Products Information | Oxygen analysers
PPM measurement
Model 2001RS Panel Mount Trace Oxygen analysers with Complete Sample System
- High resolution 3 ½ digit single range LCD
- Comprehensive state-of-the-art electronics platform, includes: simple and intuitive user interface, 2-fully adjustable alarm relay contacts, programmable alarm configurations, alarm bypass feature, programmable alarm delays, on board data logger, 3-individual security settings, internal diagnostics, remaining sensor life indication, etc.
- 10 Standard analog output ranges: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and 0-25%
- Isolated 4-20mA. analog output
Model 1000RS Portable Trace Oxygen analysers With Complete Sample System
- High-resolution 3 ½ digit single range LCD
- 10 user-selectable analog output ranges for: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and an air cal. range of 0-25%
- 0-1VDC analog output
- Data logger. Logs data for 15 days @ 1min intervals, 30 days @ 2min intervals, etc
- 1-2 year life high-performance electrochemical sensor. Optional H2S resistant sensor eliminates the need for an H2S scrubber
- Rechargeable NiCad batteries
- Very compact and rugged
- Designed to meet intrinsic safety requirements
Model 2010BR Wall Mount or 2.0" pipe Mount Hazardous Location Trace Oxygen analysers With Complete Sample System
- igh resolution 3 ½ digit single range LCD
- 10 Standard analog output ranges: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and 0-25%
- 1-5VDC and 4-20mA. analog outputs
- Patented cellblock technology. Provides 3-way selector valve: Sample/Span/Off, a flow control valve and flow meter all integral to the compact cell bloc
- 1-2 year life high-performance electrochemical sensor. Optional H2S resistant sensor eliminates the need for an H2S scrubber
- Approved by CSA International to UL and CSA standards as meeting requirements for Class I, Div. 1, Groups B,C,D with flammable gas sample
Percent Measurement
Model 201RS Panel Mount Percent Oxygen analysers with Complete Sample System
- High resolution 3 ½ LCD
- Comprehensive state-of-the-art electronics platform, includes: simple and intuitive user interface, 2-fully adjustable alarm relay contacts, programmable alarm configurations, alarm bypass feature, programmable alarm delays, on board data logger, 3-individual security settings, internal diagnostics, remaining sensor life indication, etc.
- Standard analog output ranges: 0-1%, 0-5%, 0-10% and 0-25%
- Optional analog output ranges: 0-1000ppm, 0-50% or 0-100%
- Isolated 4-20mA. analog output
- Patented cellblock technology. Provides a flow control valve, flow meter, internal span gas and isolation solenoid valves all integral to the compact cell block
General Purpose Area Classification
Model 210BR Wall Mount or 2.0" pipe Mount Hazardous Location Percent Oxygen analysers With Complete Sample System
- High resolution 3 ½ digit LCD
- Standard analog output ranges: 0-1%, 0-5%, 0-10% and 0-25%
- Optional analog output ranges: 0-1000ppm, 0-50% or 0-100%
- 1-5VDC and 4-20mA. analog outputs
- Patented cellblock technology. Provides a flow control valve, 3-way selector valve: Sample/Span/Off, and flow meter, all integral to the compact cell block
- Approved by CSA International to UL and CSA standards as meeting requirements for Class I, Div. 1, Groups B,C,D with flammable gas sample
Model 70 Panel Mount Percent Oxygen Analyser
- High resolution 3 ½ digit LCD
- Standard analog output ranges: 0-1%, 0-5%, 0-10% and 0-25%
- Optional analog output ranges: 0-50%, or 0-95%
- 0-1VDC and isolated 4-20mA. analog outputs
- Remarkably stable 10-year life zirconium oxide sensor
- 2- fully adjustable alarm relay contacts
- General Purpose Area Classification
Model 111 Series Portable Percent Oxygen analysers
High resolution 3 ½ digit LCD
- Standard analog output ranges: 0-1%, 0-5%, 0-10% and 0-25%
- Optional analog output ranges: 0-50%, or 0-95%
- On board data logger
- Remarkably stable 10-year life zirconium oxide sensor
- Flow control valve and flow meter integrated into advanced technology cellblock
- The Model 111 has been designed for positive pressure applications
- The Model 111P and 111B are designed for negative pressure to 5psig. applications and are outfitted with long life sample pumps
- All have Rechargeable NiCad batteries
- The Model 111 and Model 111P are for use in General Purpose Area Classifications
- The Model 111B has been designed to meet Class1, Div. 2, Groups C,D Area Classifications
Probe
Model 65 Percent Oxygen Probe
- 0-2.5VDC or optional isolated 4-20mA analog output
- Excellent repeatability and stability
- Weather tight package
- Barbed fittings for gas connections. Optional 1/4" compression fittings or Diffusion screen
- Low cost and virtually maintenance free over its eentire life
- Requires no support or calibration gases, other than ambient air if desired
- 10 year life sensor
Oxygen Deficiency Monitor
Model 221R Oxygen Deficiency Monitor
- Single range measurement: 0-25%,
- Optional measurement ranges available
- 0-2.5VDC analog output or optional 4-20mA. output
- Remarkably stable 10-year life zirconium oxide sensor
- Great low cost OEM solution for system integration
- General Purpose Area Classification
- Optional display/calibration module